* Prices incl. VAT plus shipping costs
Delivery time approx. 5 working days
- Order number: 10.08.07.01.02
Amplified radiometric probe for outdoor use for measuring the irradiance in the UVB spectral range (peak at 305 nm). Typical sensitivity 5 V/(W/m²), measuring range 0...1 W/m², impedance 10 KΩ, power supply 7...30 Vdc, typical current consumption 3 mA.
The radiometer LPUVB02 measures the global radiation in the UVB spectral range on a flat surface (Watt/m²). In particular, the spectral sensitivity of the instrument is centred at 305 nm with a bandwidth of 5 nm (FWHM). Global radiation is the sum of direct solar radiation and diffuse sky radiation on a surface parallel to the ground. In contrast to the visible spectrum, where the direct component predominates over the diffuse component, in the UVB spectral range the light is strongly scattered by the atmosphere and thus the two components are equal.
It is therefore of utmost importance that the instrument can accurately measure both components.
The LPUVB02 probe is typically used in the following industries:
Ozone layer monitoring. In fact, radiation around 295 nm-315 nm is strongly absorbed by ozone, which is in the stratosphere, so any small change in the ozone layer corresponds to an increase or decrease in the radiation reaching the ground.
Effects of UVB radiation (the most harmful to human health) on living organisms.
UVB radiation measurement in workrooms
Delta Ohm,LPUVB02 radiometer sensor, RADIATION STRENGTH in the UVB spectral range, 305 nm, global radiation ,UVB spectral range ,spectral sensitivity of the instrument at 305 nm , bandwidth of 5 nm (FWHM) Therefore it is of utmost importance that the
Supplied with calibration report. On request 5 or 10 m cable CPM12AA8... with 8-pin M12 connector.
Sensor Type: | UV-Radiometer |
Norm: | VDI 3786 Part 5 Radiation Measurement |
Norm - WMO: | WMO-No,8 7th Edition Part I Chapter 7 Measurement of radiation |
Application: | Agriculture, climate measurements, Environmental Protection, Hydrology, industry, Research, Solar technology, Transport Meteorology |
Manufacturer: | Kipp & Zonen |
Measurement methods: | thermopile |
Measuring range (W/m2): | 0 ... 6 W/m² |
Spectral range [nm]: | 280...315 |
Calibrated faktor: | 2 W/m²/V , 30 W/m²/V |
Dome: | Quarzglas |
Linearity: | < 1% |
Long-term stability: | 5 % |
Directional error (W / m2): | < 2,5 % (bei 70 ° Zenitwinkel) |
Operating temperature [° C]: | -40 °C ...+50 °C |
Medium: | Air |
Connection {Plug: | 4-pin shielded, 3m |
Mobile data capture radiation:: | handheld device, Multichannel datalogger, Single channel data logger |
voltage supply: | 7...18 VDC / 8 W |
Degree of protection: | IP65 |
Weight (Kg): | 1,0 |
Housing: | Aluminum cast and stainless steel painted white |