Pyranometer Secondary Standard MS-80

€2,508.80 * (€2,108.24 netto zzgl. MwSt.)

* Prices incl. VAT plus shipping costs

Delivery time 30 Workdays

Pyranometertyp:

  • 10.02.03.02
Pyra EKO’s new generation sensors broke the rules of traditional pyranometer architecture.... more
Product information "Pyranometer Secondary Standard MS-80"

Pyra

EKO’s new generation sensors broke the rules of traditional pyranometer architecture. The innovative patented design was inspired by the combination of latest technologies and state-of-the-art thermopile sensor, enabling a breakthrough in unprecedented low zero-offset behavior and fast sensor response.

The compact sensor with a single dome, based on an isolated thermopile detector and Quartz diffusor is immune to offsets and integrates all optional value-added functions such as a ventilator, heater and different industrial interfaces. The heater and ventilator are suggested, particularly in areas impacted by dew, frost, snow, and dust.

The MS-80A is an MS-80 with a built-in 4-20mA converter and MS-80M with built-in MODBUS converter. They are compatible with the industrial output standards. Due to the ultra-low temperature dependency and exceptional non-linearity characteristics, the converter guarantees an optimal sensor performance, under any environmental conditions.

The MS-80 pyranometers are manufactured in a consistent way followed by strict quality inspection and performance evaluation. For each sensor, the directional response and temperature dependency are measured and validated through a measurement report that comes with the sensor. EKO provides a unique calibration compliant to the international standards defined by ISO/IEC17025/9847.

The sensor has a 5 years warranty, 5 years recommended re-calibration interval and no longer the requirement for the desiccant to be changed.

Sensor Type: Pyranometer, Secondary Standart
Norm - WMO: WMO-No,8 7th Edition Part I Chapter 7 Measurement of radiation
Norm: VDI 3786 Part 5 Radiation Measurement
Manufacturer: EKO
Application: Agriculture, climate measurements, Environmental Protection, Hydrology, Research, Solar technology, Synoptic
Measurement methods: thermopile
Measuring element:: Thermopile
Medium: Air
Accuracy class DIN ISO 9060: Secondary Standard
Measuring range (W/m2): 0...4000
Measurement Accuracy: < 10%
Spectral range [nm]: 285...3000
Connection: Plugs removed to the side
Impedance [Ohm]: 10 bis 100 Ω
Inclination error (at 1000 W / m²): < 1 %
Levelling accuracy: 0,1°
Dome: Quarzglas
Linearity: < 1%
Directionality: f2 < 1.5%
Directional error (W / m2): < 10 W/m²
response time [t95 s]: < 1 s
Zero offset [W / m²]: < 0,2
Zero offset thermal radiation [W / m²]: < 2, < 7
Temperature dependence of sensitivity (% / ° C): < 1.0 % @(-10 … +40 ºC)
Maximum radiation [W / m²]: 4000
voltage supply: 12...24VDC
Nonlinearity: ≤ 0,15 %
Output signal : MODBUS
Housing: Aluminum cast and stainless steel painted white
Weight (Kg): 2,0
Degree of protection: IP67
Dimension (cm): L:50 X50x10 cm
Mobile data capture radiation:: handheld device, Multichannel datalogger, Single channel data logger